The Hurricane GD-1-1 entry level spray booth has Certification and 1 year guarantee.
HAS NO MANUFACTURER APPROVALS ON THIS BOOTH
Technical Data GD-1-1 Entry Level 7m Spray Booth
Description Data
External Dimentions 7000mm x (40000mm+1200MM) x 3328mm (L x W x H)
Internal Dimentions 6900mm x 3900mm x 2600mm (L x W x H)
Basement 300mm galvanized steel basement, 2 rows of grids and 3 rows of checker plate. 2 x ramps 625mm wide x 2000mm long.
Main Door 3-Folds, 3000mm x 2600mm (W x H) with square tempered glass windows
Escape Door 1 Unit, 700mm x 1860mm (W x H) with square tempered glass window
Wall Panels 50mm thick EPS fireproof, heat preservation wall panels 0.426mm steel plate EPS density = 18KG/m3
Roof Plates Galvanized steel plates 0.6mm
Lighting Ceiling Lights : 8 x Units x 3Pcs = 24 Pcs x 18W LED lights
Illumination +/- 800Lux
Glass Clear tempered glass.
Intake and Exhaust system positioning Installed at Left or Right of booth.
Intake and Exhaust System 1 x 5.5KW turbo fan for inlet 18000m3/hour – Air speed 0.2 – 0.35m/s, no exhaust fan. Air Exchanges 220/Hour
Air Capacity 18000m3/hour
Filtering System Ceiling Filter (560G/m2 efficiency >=93%) and Exhaust fiberglass filter(Under grid Paint Arrestor 250G/m2), also Pre-filter (200G M-Type Filter) and Exhaust filter (200G M-Type Filter)
Heating System Riello LG20 Diesel burner with stainless steel combustion chamber, heating productivity = 200000Kcal.
Control system Lighting switch, spraying, bake and spray for winter and baking functions, time setting, failure indicator, temperature controller, temperature limit controller, pressure gauge and hour meter.
Noise < 80 dB
Power Supply 380V 3Phase
Total Power 7KW